RX sensetivity DA14580

Dear Sir,
could you sent us a full information about sensetivity level --> according datasheet while :
DC-DC converter enabled;
Dirty Transmitter
disabled; TA = 25 °C;
PER = 30.8 %
(Note 18)

The sensetivity is -93

你能解释一下是什么/ = 30.8%吗?我往常一样y see at datasheet that sensetivity measured vs BER <0.1% or 0.2% , so what at this case 30.8%???

thanks

Device:
Jelphi
Offline
Last seen:4 months 2 weeks ago
Staff
Joined:2015-09-10 12:07
PER Test is used for BLE

PER Test is used for BLE receiver testing, as opposed to the use of BER Test for Classic Bluetooth devices. The PER requirement is
expressed as: PER < 30.8% after at least 1500 packets.
This PER requirement equates to a BER of 0.1% under a series of assumptions specified in the Test Specifications document. These
assumptions are used to describe a hypothetical (yet, realistic) situation in which the number of significant bits in an LE test packet
is 368 bits (out of a total of 376 bits), and the probability of the sequence of containing no bit errors is (1-0.1%)^368 = 0.692, hence the
resulting PER requirement is (1 - 0.692) • 100% = 30.8%.

sergey_kolen
Offline
Last seen:3 years 10 months ago
Joined:2015-10-26 10:19
1. The RX sensetivity is

1. The RX sensetivity is depend on supply voltage?
2. According datasheet typical sensetivity value is -93dBm and maximal is -70dBm . why the range is so wide?
3. If IC supplied by external DC-DC or external LDO , is matter for high performanse of sensetivity or the IC have internal filter on supply voltage?

MT_dialog
Offline
Last seen:1 month 2 weeks ago
Staff
Joined:2015-06-08 11:34
Hi sergey_kolen,

Hi sergey_kolen,

Please check your other posthttp://support.dialog-semiconductor.com/forums/post/dialog-smartbond-da1...and also dont replicate the same questions.

Thanks MT_dialog