TX Continuous Mode Not Working - Connection Manager

Dear,

When using Connection Manager to test the DA14583 device, neither the TX Continuous Test or Unmodulated TX work. I was only able to transmit using LE transmitter Test Command. However, I desire to make a continuous test. How can I configure that to work?

Attached is the log from the test.

Regards.

Device:
MT_dialog
Offline
Last seen:3 months 4 days ago
工作人员
加入:2015-06-08 11:34
Hi wapimenta,

Hi wapimenta,

Compile and download to the 583 the prod_test project that is located in the SDK (just compile it for the 583 and then use the "Load Firmware" from the connection manager in order to download it to the 583). Then hit the "Boot Test Mode" and you should be able to use the Unmodulated Rx/Tx and Tx Continuous Test.

Thanks MT_dialog

wapimenta
Offline
Last seen:4 years 2 months ago
加入:2017-03-02 16:54
Dear,

Dear,

Now it worked. Thanks for the help on this.