我正在使用da1468x网格SDK 1.6.1。
当我试图开始定期广播时,我收到了以下信息。
设备似乎工作了一段时间,最终停止与SAR上下文消息。
我怎样才能解决这个问题?
[净tx] pkt。SRC:0x010D,DST:0xFFFF,IVI:0x00,SEQ:0x0000144B,CTL:0x00,TTL:0x7F,Len:16,IS_Relay:0x00 [Net TX] PKT。SRC:0x010D,DST:0xFFFF,IVI:0x00,SEQ:0x0000144C,CTL:0x00,TTL:0x7F,Len:6,IS_Relay:0x00 [Net TX] PKT。SRC:0x010D,DST:0xFFFF,IVI:0x00,SEQ:0x0000144D,CTL:0x00,TTL:0x7F,Len:16,IS_Relay:0x00 [Net TX] PKT。SRC:0x010D,DST:0xFFFF,IVI:0x00,SEQ:0x0000144E,CTL:0x00,TTL:0x7F,Len:6,IS_Relay:0x00 [** Err **]:[ltrn_replay_cache.c]:[689]:[LTRN] ACK RTX定时器启动失败[NET RX] PKT。SRC:0xFFFF,DST:0x010D,IVI:0x00,SEQ:0x00002C66,CTL:0x01,TTL:0x7F,NID:0x72 [** Err **]:[net_init.c]:[net rx] srcAddr 0xffff不是单播地址。丢弃... [净rx] pkt。SRC:0xFFFF,DST:0x010D,IVI:0x00,SEQ:0x00002C66,CTL:0x01,TTL:0x7F,NID:0x72 [** Err **]:[net_init.c]:[net rx] srcAddr 0xffff不是单播地址。 Dropping... [NET Rx] Pkt. SRC:0xFFFF, DST:0x010D, IVI:0x00, SEQ:0x00002C66, CTL:0x01, TTL:0x7F, NID:0x72 [** ERR **]:[net_init.c]:[234]: [NET Rx] SRC ADDR 0xFFFF not a Unicast Address. Dropping... [NET Rx] Pkt. SRC:0xFFFF, DST:0x010D, IVI:0x00, SEQ:0x00002C66, CTL:0x01, TTL:0x7F, NID:0x72 [** ERR **]:[net_init.c]:[234]: [NET Rx] SRC ADDR 0xFFFF not a Unicast Address. Dropping... [NET Rx] Looks like we are processing a relayed packet! [NET Rx] Pkt. SRC:0x010D, DST:0xFFFF, IVI:0x00, SEQ:0x00001445, CTL:0x00, TTL:0x7E, NID:0x72 [LTRN Rx] Pkt originated from Local SRC. Some repeater probably send back our message.. Dropping... [NET Rx] Pkt. SRC:0xFFFF, DST:0x010D, IVI:0x00, SEQ:0x00002C67, CTL:0x01, TTL:0x7F, NID:0x72 [** ERR **]:[net_init.c]:[234]: [NET Rx] SRC ADDR 0xFFFF not a Unicast Address. Dropping... [NET Rx] Looks like we are processing a relayed packet! [NET Rx] Pkt. SRC:0x010D, DST:0xFFFF, IVI:0x00, SEQ:0x0000144B, CTL:0x00, TTL:0x7E, NID:0x72 [LTRN Rx] Pkt originated from Local SRC. Some repeater probably send back our message.. Dropping... [** ERR **]:[ltrn_replay_cache.c]:[489]: [LTRN] Failed to allocate SAR Context. Returning [** ERR **]:[ltrn_api.c]:[312]: [LTRN Tx] SAR Context Allocation for Tx Failed. Battery Check ...95% [** ERR **]:[ltrn_replay_cache.c]:[489]: [LTRN] Failed to allocate SAR Context. Returning [** ERR **]:[ltrn_api.c]:[312]: [LTRN Tx] SAR Context Allocation for Tx Failed. [** ERR **]:[ltrn_replay_cache.c]:[489]: [LTRN] Failed to allocate SAR Context. Returning [** ERR **]:[ltrn_api.c]:[312]: [LTRN Tx] SAR Context Allocation for Tx Failed. [** ERR **]:[ltrn_replay_cache.c]:[489]: [LTRN] Failed to allocate SAR Context. Returning
设备:

嗨Firebird,
我正在在内部与我们的团队一起工作。尽快解决解决方案。
最好的,
LC_Dialog
嗨Firebird,
为了帮助解决这个问题,我们需要更多关于您的实现的信息。能否提供以下详细信息?
您对应用程序进行了哪些变化?
您使用了多少个节点?
你多久广播一次数据?
发送的数据包的大小是多少?
此致,
LC_Dialog
嗨,团队,
我对网格示例进行了几个更改。特别是修改的供应商服务器/客户端模型。
太多了,不能在这篇文章中列出,所以首先我想知道这个错误的根本原因。
1.我有两个节点,一个是供应商服务器,另一个是供应商客户端模型,但当只有一个供应商服务器运行时,相同的错误发生。所以,我认为只有一个节点有供应商服务器模型可能有问题。
2.广播周期为10秒。
3.每个广播包的数据部分为13字节。
额外的观察:
1.播出时间没有关系。当我将周期改为1秒时,设备在16次成功传输后显示相同的错误。
更换周期和测试多次,设备总是在第16 tx后失败。
2.当我减少数据包大小时,5字节是阈值。如果数据包大小小于5,则不会出现数据包分片,也不会出现错误。
但是,如果数据包大小超过5,则总是会发生错误。
3.顺便说一下,以下消息在非片段条件下也消失了。为什么?
嗨Firebird,
谢谢分享细节。我们正在调查。
此致,
LC_Dialog
此问题未完成。
为什么这个问题被标记为“已完成”?
我还在等待反馈。
嗨Firebird,
我不确定为什么要完成它。你是对的,它正在进行中。我会得到检查。
另外,我们正在处理你的两个悬而未决的问题,下周应该可以提供一些更新。
此致,
LC_Dialog
提醒……
修饰更新......