中央密苏里州de and External CPU

11 posts / 0 new
Last post
lolo@electricimp.com
Offline
Last seen:6 years 10 months ago
加入:2014-01-22 19:12
中央密苏里州de and External CPU

Has anyone managed to run the DA14580 in Central mode? All the examples posted here are Peripheral mode.
Alternatively, has anyone managed to talk HCI/GTL to the DA14580 from an external CPU?

JE_Dialog
Offline
Last seen:1 day 14 hours ago
Staff
加入:2013-12-05 14:02
Hello Lolo, I'll have the

Hello Lolo, I'll have the local team contact you to discuss the HCI option and specific examlpes we have for central mode. We have one example that is external MCU running proximity application.

BR JE_Dialog

andrewlinton
Offline
Last seen:6 years 9 months ago
加入:2014-04-01 02:03
I have a very similar

I have a very similar question. Do you have any central mode examples? and can you switch between central or peripheral with say, a button?

JE_Dialog
Offline
Last seen:1 day 14 hours ago
Staff
加入:2013-12-05 14:02
Hello Andrew, the main

Hello Andrew, the main central mode example we have today is the proximity monitor, using an external MCU which is in the SDK. We have customers using the device in role switching mode, but we dont have that as a released demo yet. Let me check on that for you.

BR JE_Dialog

JE_Dialog
Offline
Last seen:1 day 14 hours ago
Staff
加入:2013-12-05 14:02
Hello Andrew, we dont have

Hello Andrew, we dont have anything coming in the next month as a released 'out of the box' demo for role switching . For external processor apps, we have just released an apps note on the GTL implementation : the URL is below.

http://support.dialog-semiconductor.com/um-b-017-gtl-interface-integrated-process-application

The role switching examples i would anticipate will come sometime later in Q3. We have customers who have made their own propietary solution on the DA14580 with a peripheral/central role swap.

BR JE_Dialog

nmirza
Offline
Last seen:5 years 1 month ago
加入:2014-07-24 13:08
Any updates on a stand-alone

Any updates on a stand-alone central mode example/template?

JE_Dialog
Offline
Last seen:1 day 14 hours ago
Staff
加入:2013-12-05 14:02
**** nmirza, nothing to

Hell nmirza, nothing to report on this right now. BR JE_Dialog

ohtcom
Offline
Last seen:1 year 1 week ago
加入:2014-10-16 05:08
I think GTL is very similar

I think GTL is very similar with HCI functionally.

Why there are two options, the GTL and HCI?

JE_Dialog
Offline
Last seen:1 day 14 hours ago
Staff
加入:2013-12-05 14:02
Ho ohtcom , the GTL and HCI

Ho ohtcom , the GTL and HCI are two different approaches :

HCI : DA14580 acts as a standard Bluetooth HCI controller which supports dynamic Interface & Power Management Configuration. Everything above

GTL : Link layer, host protocols and Profiles run on the DA14580. Application controls DA14580 via Dialog proprietary HCI Generic Transport Layer (GTL).

Please note : DA14581 is optimised for HCI .

BR JE_Dialog

sabasit
Offline
Last seen:1 year 1 month ago
Expert
加入:2014-10-14 14:20
Hi JE_Dialog,

Hi JE_Dialog,
Are any role switching examples available yet?

Thanks,
Basit

MT_dialog
Offline
Last seen:3 months 4 days ago
Staff
加入:2015-06-08 11:34
Hi sabasit,

Hi sabasit,

No, we have no example availabale but you can refer to your other posthttp://support.dialog-semiconductor.com/can-i-make-da14580-switch-betwee....

Thanks MT_dialog